Eilersen Weighing Modules

Eilersen Weighing Modules

Looking for Eilersen Weighing Modules? Contact us here.

Eilersen Weighing Modules enable connection of Eilersen Digital Capacitive load cells via simple BNC connections. Several variations of the modules are available based on the number of load cells to be connected as well as the communication protocol that is required. Part numbers are based on the following nomenclature:

Example: 4140A
4= 4000 series weighing module
1= 1 load cell to be connected
40= RS485 communication protocol
A= ATEX Rated

Get quote for weighing modules

Eilersen Weighing Modules

profibus digital load cell interface module
ATEX Profibus DP Interface Module 4X35A
Where “X” is the number of cells to be connected, up to (4). Interface is Profibus DP. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications
digital load cell interface module
ATEX Serial Interface Module 4X40A
Where “X” is the number of cells to be connected, up to (4). Serial interface is via RS485. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications
digital load cell interface module
ATEX Modbus TCP/IP Interface Module 4x50A
ATEX and IECEx certified (zone 1, 2, 21, 22) Modbus TCP/IP interface module for directly interfacing up to four digital ATEX / IECEx load cells. The interface module type 4X50A can also be used in non-ATEX installations
digital load cell interface module
ATEX EtherNet/IP Interface Module 4X50A
Where “X” is the number of cells to be connected, up to (4). Optional interface of Modbus TCP/IP or Ethernet/IP from the same module. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications
ethercat digital load cell interface module
ATEX EtherCAT Interface Module 4X60A
Where “X” is the number of cells to be connected, up to (4). Interface is EtherCat. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications
atex profinet digital load cell interface module
ATEX PROFINET Interface Module 4X70A
Where “X” is the number of cells to be connected, up to (4). Interface is PROFINET. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications
digital load cell interface module
Analog Output Module 4X79A
Where “X” is the number of cells to be connected, up to (4). Output is Analog 0-10Vdc or 4-20mA or via digital Ethernet interface. Also provides (4) I/O’s for alarms or remote zeroing. ATEX and IECEx rated (zone 1, 2, 21, 22). Also suitable for non ATEX applications

5008OEM Weighing Board- Enables connection of up to 8 Eilersen Digital Capacituive load cells. Specially designed for OEM applications with customized protocols. Interface is via RS4845 serial interface or EtherNet capability.

load cell interface
OEM Weighing Board 5008OEM
OEM weighing board for interfacing up to 8 digital load cells to PLCs, PCs etc. This weighing board is developed for OEM use and can be equipped with customized protocols
Load cell interface module
Serial Interface Module 4140OEM
Specially designed for OEM applications where one load cell is to be interfaced with a PLC or a PC. Serial interface is via RS485.

Blogs & case studies related to load cells

single use pupsit assemblies image 2

Single-Use PUPSIT Assemblies

If you are in need of a single-use assembly that meets all requirements for Pre-Use-Post-Sterilization-Integrity-Testing…